The Advanced Process Multi-Scanner offers unique time-saving and automation solutions to calibrate multiple pressure or temperature sensors simultaneously. Each ASM contains an eight channel scanner controlled by Jofracal software on a PC. It can handle signals from 2-, 3-, and 4- wire RTDs, TCs, transmitters, thermistors, and temperature and voltage switches. Up to 3 ASM units can be stacked to calibrate up to 24 sensors at the same time.

The ASM may be combined with any JofraCal compatible pressure calibrator, dry-block or liquid calibrators, DTI reference thermometers, and ASC multi-function process calibrators. Use any place where temperature measurement is critical and there is a need to create traceable documents for sensor calibration.

  • Automatic procedures reduce human error
  • Dedicate one input channel to a reference sensor with accuracy to 0.026°C
  • Uses True Ohm technology to eliminate EMF from cables, sockets, and sensors
  • A models use a separate measuring unit as the standard, and B models have built-in measurement capabilities

Combined with JofraCal or JofraLog you can:

  • Set-up, execute, print, and save traceable calibration data
  • Calibrate up to 24 sensors using a dry-block calibrator as the reference
  • Calibrate using a high accuracy temperature reference probe directly with the ASM
  • Data-log up to 24 sensors simultaneously
  • Inputs for Thermocouple Calibration

ASM Series Process Multi-Scanner

The Advanced Process Multi-Scanner offers unique time-saving and automation solutions to calibrate multiple pressure or temperature sensors simultaneously. Each ASM contains an eight channel scanner controlled by Jofracal software on a PC. It can handle signals from 2-, 3-, and 4- wire RTDs, TCs, transmitters, thermistors, and temperature and voltage switches. Up to 3 ASM units can be stacked to calibrate up to 24 sensors at the same time.

The ASM may be combined with any JofraCal compatible pressure calibrator, dry-block or liquid calibrators, DTI reference thermometers, and ASC multi-function process calibrators. Use any place where temperature measurement is critical and there is a need to create traceable documents for sensor calibration.

  • Automatic procedures reduce human error
  • Dedicate one input channel to a reference sensor with accuracy to 0.026°C
  • Uses True Ohm technology to eliminate EMF from cables, sockets, and sensors
  • A models use a separate measuring unit as the standard, and B models have built-in measurement capabilities

Combined with JofraCal or JofraLog you can:

  • Set-up, execute, print, and save traceable calibration data
  • Calibrate up to 24 sensors using a dry-block calibrator as the reference
  • Calibrate using a high accuracy temperature reference probe directly with the ASM
  • Data-log up to 24 sensors simultaneously
  • Inputs for Thermocouple Calibration