- Home
- Products
- Reference Temperature SensorsTemperature
- DLC System
Overview
Specification
Download
Video
Overview
DLC System
The DLC Dynamic Load Compensation System is yet another state-of-the-art innovation within temperature calibration. The DLC compensates for the negative effect on calibration accuracy that heat exchange between a dry-block calibrator and the sensor-under-test creates.
When a sensor is inserted into a dry-block calibrator, the sensor size (diameter and length) and the difference between calibration temperature and ambient temperature create an axial gradient deviation inside the insert. Our temperature calibrators are already famous for their active dual-zone calibration principle, and the DLC takes this one step further, now compensating inside the insert. The DLC, combined with an RTC Calibrator, creates the only dry-block that compensates for the heat dissipation caused by sensor loading.
- Control the lower section of the insert to within a few hundredths of a degree
- The DLC indicator shows that the dual-zone is active and working
- A DLC checkmark is present when temperature homogeneity is achieved
- Save time by calibrating several sensors simultaneously
- Calibrate large diameter sensors without losing accuracy
- Aligning the thermo-sensitive part of the sensor is no longer needed
Specification
- DLC155 Differential TC type T. Probe length: 177 mm (6.96 in). Temperature range: -60 to 155°C. Diameter: 3 mm (0.12 in) OD. Depth: 140 mm (5.51 in). Media compatibility: AISI316. Connection: Redel plug with built in memory
- DLC158 Differential TC type T. Probe length: 196 mm (7.72 in). Temperature range: -60 to 155°C. Diameter: 3 mm (0.12 in) OD. Depth: 140 mm (5.51 in). Media compatibility: AISI316. Connection: Redel plug with built in memory
- DLC159 Differential TC type T. Probe length: 196 mm (7.72 in). Temperature range: -100 to 155°C. Diameter: 3 mm (0.12 in) OD. Depth: 140 mm (5.51 in). Media compatibility: AISI316. Connection: Redel plug with built in memory
- DLC187 Differential TC type T. Probe length: 177 mm (6.96 in). Temperature range: -60 to 180°C. Diameter: 3 mm (0.12 in) OD. Depth: 140 mm (5.51 in). Media compatibility: AISI316. Connection: Redel plug with built in memory
- DLC250 Differential TC type T. Probe length: 196 mm (7.72 in). Temperature range: 0 to 250°C. Diameter: 3 mm (0.12 in) OD. Depth: 140 mm (5.51 in). Media compatibility: AISI316. Connection: Redel plug with built in memory
- DLC700 Differential TC type T. Probe length: 230 mm (9.05 in). Temperature range: 0 to 700°C. Diameter: 4 mm (0.16 in) OD. Depth: 200 mm (7.9 in). Media compatibility: AISI316. Connection: Redel plug with built in memory
- RTC-156 -30 to 155°C (-22 to 311°F), Dry Block. Use DLC-155.
- RTC-157 -45 to 155°C (-49 to 311°F), Dry Block. Use DLC-155.
- RTC-158 -22 to 155°C (-8 to 311°F), Dry Block / Liquid Bath. Use DLC-158.
- RTC-159 -100 to 155°C (-148 to 311°F), Ultra Cooler. Use DLC-159.
- RTC-187 -45 to 180°C (-49 to 356°F), Dry Block. Use DLC-187.
- RTC-250 28 to 250°C (82 to 482°F), Dry Block / Liquid Bath. Use DLC-250.
- RTC-700 33 to 700°C (91 to 1292°F), Dry Block. Use DLC-700.
Download
Video
No video found.
Overview →
Specification →
Download →
Video →
Overview →
DLC System
The DLC Dynamic Load Compensation System is yet another state-of-the-art innovation within temperature calibration. The DLC compensates for the negative effect on calibration accuracy that heat exchange between a dry-block calibrator and the sensor-under-test creates.
When a sensor is inserted into a dry-block calibrator, the sensor size (diameter and length) and the difference between calibration temperature and ambient temperature create an axial gradient deviation inside the insert. Our temperature calibrators are already famous for their active dual-zone calibration principle, and the DLC takes this one step further, now compensating inside the insert. The DLC, combined with an RTC Calibrator, creates the only dry-block that compensates for the heat dissipation caused by sensor loading.
- Control the lower section of the insert to within a few hundredths of a degree
- The DLC indicator shows that the dual-zone is active and working
- A DLC checkmark is present when temperature homogeneity is achieved
- Save time by calibrating several sensors simultaneously
- Calibrate large diameter sensors without losing accuracy
- Aligning the thermo-sensitive part of the sensor is no longer needed
Specification →
- DLC155 Differential TC type T. Probe length: 177 mm (6.96 in). Temperature range: -60 to 155°C. Diameter: 3 mm (0.12 in) OD. Depth: 140 mm (5.51 in). Media compatibility: AISI316. Connection: Redel plug with built in memory
- DLC158 Differential TC type T. Probe length: 196 mm (7.72 in). Temperature range: -60 to 155°C. Diameter: 3 mm (0.12 in) OD. Depth: 140 mm (5.51 in). Media compatibility: AISI316. Connection: Redel plug with built in memory
- DLC159 Differential TC type T. Probe length: 196 mm (7.72 in). Temperature range: -100 to 155°C. Diameter: 3 mm (0.12 in) OD. Depth: 140 mm (5.51 in). Media compatibility: AISI316. Connection: Redel plug with built in memory
- DLC187 Differential TC type T. Probe length: 177 mm (6.96 in). Temperature range: -60 to 180°C. Diameter: 3 mm (0.12 in) OD. Depth: 140 mm (5.51 in). Media compatibility: AISI316. Connection: Redel plug with built in memory
- DLC250 Differential TC type T. Probe length: 196 mm (7.72 in). Temperature range: 0 to 250°C. Diameter: 3 mm (0.12 in) OD. Depth: 140 mm (5.51 in). Media compatibility: AISI316. Connection: Redel plug with built in memory
- DLC700 Differential TC type T. Probe length: 230 mm (9.05 in). Temperature range: 0 to 700°C. Diameter: 4 mm (0.16 in) OD. Depth: 200 mm (7.9 in). Media compatibility: AISI316. Connection: Redel plug with built in memory
- RTC-156 -30 to 155°C (-22 to 311°F), Dry Block. Use DLC-155.
- RTC-157 -45 to 155°C (-49 to 311°F), Dry Block. Use DLC-155.
- RTC-158 -22 to 155°C (-8 to 311°F), Dry Block / Liquid Bath. Use DLC-158.
- RTC-159 -100 to 155°C (-148 to 311°F), Ultra Cooler. Use DLC-159.
- RTC-187 -45 to 180°C (-49 to 356°F), Dry Block. Use DLC-187.
- RTC-250 28 to 250°C (82 to 482°F), Dry Block / Liquid Bath. Use DLC-250.
- RTC-700 33 to 700°C (91 to 1292°F), Dry Block. Use DLC-700.